Why treat compressed air?
|
Contaminants in compressed air adversely affect all components of the air distribution
system
Wet, dirty compressed air costs money by:
- Robbing the system of useful power
- Air lines rust and leak
- The power and efficiency of air tools decreases
Increasing maintenance and repair expenses:
- Lubricants wash out of air tools
- Solid particles abrade wear surfaces
Contributing to product rejects:
- The color/adherence of paint spraying is affected
- Product spoilage in food processing is promoted
With the proper compressed air treatment equipment, system power is maintained,
operating expenses are reduced, and production quality is improved. The cost of
using wet air far exceeds the cost of keeping it dry!
|
|
|
|
Where does moisture come from?
|
Atmospheric air always contains moisture,or water vapor.
The amount of moisture air can retain is determined by its temperature and,
to a lesser extent, its pressure. Any sufficient drop in temperature or increase
in pressure will cause moisture to condense out of the air.
Relative humidity is the amount of moisture that is present in the air, compared
to the total amount the air could hold at a certain temperature. For example: One
cubic foot of air at 80°F, 27°C can hold about 12 grains of moisture.
If it is holding all 12 grains, it is said to be at 100% relative humidity or
saturated. If that same cubic foot of air is holding only 6 grains of moisture,
it is at 50% relative humidity.
Saturation point is the point at which air is holding all the water vapor it
can (100% relative humidity). If we added more water vapor to saturated air, the
water vapor would condense into a liquid.
Remember that a drop in temperature or increase in pressure will cause moisture
to condense out of air that is saturated.
Condensation is the changing of water vapor into a liquid.
Dew point is the temperature at which water vapor in the air condenses into
a liquid.
Pressure dew point is more meaningful because it indicates, at a given pressure,
the temperature at which condensate forms in the compressed air lines.
|
|
|
|
How do these concepts relate to a compressed air system?
|
Contaminants in compressed air adversely affect all components of the air distribution
system
Water vapor and other contaminants in the ambient air enter the compressor intake.
One cubic foot of air at atmospheric pressure contains:
- Liquids - Water droplets
- Solids - Dust and pipe scale
- Gases - Oil and water vapors
Once atmospheric air passes through a compressor operating at 100 psig; 7 bar,
the air is compressed to 1/8th its previous volume, yet still contains the same
amount of contaminants.
The increase in pressure would normally cause moisture to condense out of the
air, however, during the compression process, the temperature of the air rises due
to frictional heat, increasing its ability to hold water vapor.
As air leaves the compressor and travels throughout the system, it begins to
cool. Once the air temperature drops below the pressure dew point temperature, water
droplets begin to condense.
Condensation is the changing of water vapor into a liquid.
It is necessary to remove the moisture and contaminants from the air system
in order to lower the dew point and avoid operating problems, costly maintenance,
and repair expenses.
Important Guideline: For every 20°F, 11°C drop in compressed air temperature,
the moisture holding capacity of air is reduced by 50%.
|
|
|
|
How are moisture and contaminants removed?
|
Aftercoolers are a good first step. They lower the compressed air temperature
to safe, usable levels and remove up to 70% of the water vapor; however, the air
is still saturated. A further drop in temperature will cause additional condensation
to occur in downstream air lines.
Water vapor and other contaminants in the ambient air enter the compressor intake.
Air dryers remove the water vapor and lower the dew point temperature of compressed
air. This prevents liquid water from forming downstream, but does not eliminate
all the entrained contaminants.
Separators and filters remove the liquid water, and solid and gaseous contaminants
that adversely affect the air system.
Drains discharge the accumulated water and liquid contaminants from various
points throughout the air system.
Condensation is the changing of water vapor into a liquid.
|
|
|
|
Why and when should I clean the condensing unit on my refrigerated air dryer?
|
Dust and dirt that accumulate on the condenser coil of an air-cooled refrigerated
dryer will hamper the dryer’s ability to produce a consistent outlet dew point,
and ultimately to function at all. The condenser coil should be cleaned a minimum
of once a month to prevent this from happening.
|
|
|
|
How do I select the right air dryer?
|
When selecting a compressed air dryer, consider these factors and then determine
the most cost-effective system suitable for the application.
Compressed air dryers vary in relation to their dew point, initial cost, and
ongoing maintenance requirements.
- Choose a dew point temperature below the lowest ambient
temperature to which your compressed air system will be exposed.
Consider air lines:
- Located in front of open doors or windows
- Throughout air conditioned or unheated areas
- Running underground or between buildings
- Determine which dryers will produce the required dew
point.
- Consider initial and operating costs. The lower the
dew point, the more expensive the dryer is to purchase and operate
|
|
|
|
How do I calculate the correct size dryer?
|
Once the appropriate drying system has been selected, determine the actual conditions
under which the dryer will be operating.
- Flow capacity (scfm, Nm3/hr, Nm3/min,
l/sec)
- Pressure dew point (°F, °C)
- Inlet air pressure (psig, bar, kg/cm2)
- Inlet air temperature (°F, °C)
- Ambient or cooling water temperature (°F,°C)
- Maximum allowable pressure drop (psi, bar, kg/cm2)
In North America, in accordance with CAGI ADF100, conditions for rating compressed
air dryers are: 100 psig (7 bar), 100°F (38°C) saturated inlet, 85°F
(25°C) cooling water, 100°F (38°C) ambient air and a maximum 5 psi (0.35
bar) pressure drop.
In Europe, and much of the rest of the world, the ISO 7183 standard for rating
compressed air dryers is used: 7 bar (100 psi), 35°C (95°F) inlet, 25°C
(77°F) ambient air and a maximum 0.35 bar (5 psi) pressure drop.
When operating at other than rated conditions, adjustments to the dryer’s rated
flow capacity must be made.
|
|
|
Warranty & Product Registration
Register your Hankison product here!
Click for Product Registration
Product Selector
Select a product from the list below:
Technical Support
Mr. Dew, Hankison's Technical Support Concierge, is available to answer your technical
questions regarding a specific Hankison product or application.
Click for Technical Support
The Latest News
|
February 2012
|
SPX Flow Technology Launches Two New Technologies to
the Hankison Product Line!
SPX brand is pleased to introduce the new HES Series
high capacity refrigerated air dryer and HCD Series heat of compression desiccant
air dryer...
|
|
Download the press release >>
|
|
|
|
November 2011
|
Hankison Branding Change
You may notice some changes to the Hankison logo and
other product brand logos of SPX. To more visibly connect these logos to our parent
company, we’ve made slight changes to the logo designs...
|
|
Read More >>
|
|
|
|
August 2009
|
A Discussion on Air Quality Standards ISO 8573.1 and
ISO 12500 By Jay Francis, Vice President of Marketing, SPX Dehydration & Filtration.
The next time you sit down for dinner, take a good look
at your food. There’s a very good chance compressed air played an essential role
in preparing your meal for consumption. Compressed air is a vital energy source...
|
|